  • Data Center Map

    Cogent Charlotte


    » Index » USA » North Carolina » Charlotte » Cogent Charlotte

    Cogent Charlotte is located in the area Charlotte, USA (America), and the colocation data center is carrier neutral. The data center was last updated on 23-12-2019.


    Address:
    Cogent Communications, Inc.
    701 East Trade Street
    28202 Charlotte
    North Carolina, USA

    » Request quote
    » Visit website

    Click here to find other data centers
    owned and operated by Cogent Communications, Inc..


    Profile
    Tenants
    Connectivity
    Request quote
    Office space
    Rack Cabinets
    Dedicated Servers
    Suites
    Footprints
    Virtual Servers
    Cages
    Hosting of individual servers
    Remote Hands

    Profile


    On-Net Products
    . IP Transit
    . Ethernet Transport Services

    Standard Rack Configuration
    . 42U Cabinets (Type: APC AR3100)
    . Power extra (1) 110v/20 amp or (2) 110v/20A is standard

    Facilities
    . 480v 3-phase utility feed - 1,200 amps
    . 2,989 square feet of non raised floor data center space
    . WIFI Available

    Security
    . C*CURE Software House Card Reader Access Control System
    . Building system access badge required for entry at all times building doors locked down 24/7/365
    . (4) IP cameras in use with recording and 24/7/365 monitoring capabilities to the Cogent NOC (1) at main entrance into facility

    UPS Systems
    . (1) UPS Unit - 250 kVA
    . Model: Schneider Electric Galaxy VM
    . (1) Modular Battery Cabinet

    Generator Systems
    . 600kW Caterpillar Diesel Generator
    . 600 gallon diesel fuel storage tank

    Electrical
    . Automatic Transfer Switch (1,200 amps) - RussElectric
    . (1) Schneider Electric "InfraStruxure" PDU - 150KVA

    Fire Systems
    . Fire suppression and detection system consists of heat detectors, smoke heads and a preaction sprinkler system
    . 24/7/365 Monitored

    HVAC
    . (6) Liebert 20-ton HVAC units in Data Center Rooms
    . (1) Liebert 10-ton HVAC Unit in the Electrical Room
    . Rooftop mounted condenser units

    For informational purposes only. Cogent does not guarantee the information set forth above and it may be changed without notice.


    Cogent Charlotte Pricing/Quotes


    If you are interested in receiving a quote for Cogent Communications, Inc., please try our free quote service.

    Copyright © Data Center Map - Sitemap
    Your guide to colocation data centers, managed hosting, cloud servers etc.
    久久精品国产只有精品
  • <small id="ousky"></small><xmp id="ousky"><li id="ousky"></li>
  • <xmp id="ousky"><td id="ousky"></td><td id="ousky"></td><small id="ousky"><td id="ousky"></td></small>
  • <small id="ousky"><td id="ousky"></td></small>
  • <small id="ousky"><li id="ousky"></li></small>
  • <small id="ousky"><li id="ousky"></li></small>
  • <td id="ousky"></td>
  • <td id="ousky"></td><small id="ousky"></small>
  • <td id="ousky"></td>