  • Data Center Map

    LightEdge Data Center - Altoona I


    » Index » USA » Iowa » Des Moines » LightEdge Data Center - Altoona I

    LightEdge Data Center - Altoona I is located in the area Des Moines, USA (America), and the colocation data center is carrier neutral. The data center was last updated on 30-07-2018.


    Address:
    LightEdge
    1435 Northridge Circle NE
    50009 Altoona
    Iowa, USA

    » Request quote
    » Visit website

    Click here to find other data centers
    owned and operated by LightEdge.


    Profile
    Tenants
    Connectivity
    Request quote
    Office space
    Rack Cabinets
    Dedicated Servers
    Suites
    Footprints
    Virtual Servers
    Cages
    Hosting of individual servers
    Remote Hands

    Profile


    Location
    LightEdge's flagship data center, Altoona I, is located in Central Iowa, near the junction of Interstate 80 and Interstate 35. The land is known to be flood resistant and geologically stable. Central Iowa has consistently been ranked as one of the lowest-risk areas for data center placement. Nearly
    the entire state falls in Seismic Zone "0" and there are no suspected terror threat sites within the state.

    Facility
    The pre-cast, fully insulated concrete structure has been designed and tested to withstand sustained 200 MPH winds, and is enclosed with a dry design, double membrane concrete roof. Air handling units and other equipment is housed at ground level, rather than the roof, to avoid any unnecessary membrane penetrations.

    Data Center Designed for Next Generation Components
    The facility is designed to accommodate the increasing power and cooling demands of next-generation computing and storage environments such as Blade Centers and SANs. While the per square- foot requirements of these new platforms are often too demanding for existing facilities, the power and cooling architectures of Altoona I were specifically designed to meet current and future equipment specifications.

    On-site Data Center Support Staff
    This data center is staffed by technical experts that can provide on-site support for any customer requirements, 24 hours per day, 365 days per year. They also provide continuous monitoring for the facility to ensure access security and seamless operations.

    Fully Redundant Power Supply
    Altoona I is serviced through two independent power grid substations. In the event of an outage on one grid, utility switching automatically routes to the alternate substation. In the event of a complete loss of power at both locations, UPS systems provide uninterrupted power to the data center facilities while the building switches over to on-site diesel back-up generators.


    Features:
    [X] 24/7 access
    [X] 24/7 staff on side
    [X] 24/7 security guard(s)
    [X] Remote hands available
    [X] Automatic fire suppression
    [X] Environmental Monitoring
    [X] Video surveillance
    [X] Alarm system
    [X] Aircondition
    [X] Generator
    [X] UPS

    Services:
    [X] Rental of suites/rooms
    [X] Rental of cages
    [X] Rental of foot prints
    [X] Rental of racks
    [X] Hosting of individual servers
    [X] Dedicated servers
    [X] Virtual servers
    [X] Office space

    Contact LightEdge at (877) 771-3343 or at info@lightedge.com for more information.


    LightEdge Data Center - Altoona I Pricing/Quotes


    If you are interested in receiving a quote for LightEdge, please try our free quote service.

    Copyright © Data Center Map - Sitemap
    Your guide to colocation data centers, managed hosting, cloud servers etc.
    久久精品国产只有精品
  • <small id="ousky"></small><xmp id="ousky"><li id="ousky"></li>
  • <xmp id="ousky"><td id="ousky"></td><td id="ousky"></td><small id="ousky"><td id="ousky"></td></small>
  • <small id="ousky"><td id="ousky"></td></small>
  • <small id="ousky"><li id="ousky"></li></small>
  • <small id="ousky"><li id="ousky"></li></small>
  • <td id="ousky"></td>
  • <td id="ousky"></td><small id="ousky"></small>
  • <td id="ousky"></td>