  • Data Center Map

    SMS Datacenter


    » Index » USA » California » Irvine » SMS Datacenter

    SMS Datacenter is located in the area Irvine, USA (America), and the colocation data center is carrier neutral. The data center was last updated on 03-10-2018.


    Address:
    SMS Datacenter
    2525 Main Street Suite 120
    92614 Irvine
    California, USA

    » Request quote
    » Visit website

    Click here to find other data centers
    owned and operated by SMS Datacenter.


    Profile
    Tenants
    Connectivity
    Request quote
    Office space
    Rack Cabinets
    Dedicated Servers
    Suites
    Footprints
    Virtual Servers
    Cages
    Hosting of individual servers
    Remote Hands

    Profile


    The SMS Datacenter located in Irvine, California was completely upgraded in 2009 as demand
    for capacity has increased for both power and cooling. The PUE (Power Utilization Efficiency) is
    always being reduced through technology upgrades. The facility meets the highest availability
    standards for housing mission critical computer systems, and is SOC2 audited annually. The purpose
    built facility contains a total area of 41,000 square feet and is a fully secure, disaster safe, state of the
    art steel structure with complete electrical, mechanical, and environmental back-up systems.
    The facility has power generation capability housing both internal and external diesel generators
    including three fully 2N redundant Powerware UPS systems. There is over 10,000 gallons of diesel fuel
    onsite providing over 72 hours at 100% load of up time. The Automatic Transfer Switches (ATS) are
    tested monthly, which can simulate the loss of utility power.
    The infrastructure includes a self-contained, automatically controlled environment maintained by over
    6.5 million BTUs of air-cooled CRAC units with dedicated roof mounted condensers for the exclusive
    use of the raised floor. Each APC cabinet has three phase, 208 Volt redundant powers strips (PDUs)
    with both copper patch panels and fiber optic enclosures providing a redundant plug and play fabric.
    To prevent unauthorized entry to the facility, SMS Datacenter has 24x7 staff onsite, and a security system
    that controls access into and within the building, automatically limiting access to sensitive areas.
    Access is also logged automatically within a secure database. Additionally, cameras are installed both
    inside and outside the building with DVR recording. With displays in the fully manned Network
    Operation Center (NOC) and at the security desk, the premises are constantly monitored by a
    comprehensive security system. A uniform guard also operates security after business hours.
    There is infrastructure that can be brought online to provide an additional 2000 Amps of Power from a
    separate dual substation transformer feed with both generator paralleling gear and ATSs. Redundancy
    can also be achieved in cooling by bringing the existing redundant 270 ton cold water chillers online.


    SMS Datacenter Pricing/Quotes


    If you are interested in receiving a quote for SMS Datacenter, please try our free quote service.

    Copyright © Data Center Map - Sitemap
    Your guide to colocation data centers, managed hosting, cloud servers etc.
    久久精品国产只有精品
  • <small id="ousky"></small><xmp id="ousky"><li id="ousky"></li>
  • <xmp id="ousky"><td id="ousky"></td><td id="ousky"></td><small id="ousky"><td id="ousky"></td></small>
  • <small id="ousky"><td id="ousky"></td></small>
  • <small id="ousky"><li id="ousky"></li></small>
  • <small id="ousky"><li id="ousky"></li></small>
  • <td id="ousky"></td>
  • <td id="ousky"></td><small id="ousky"></small>
  • <td id="ousky"></td>