                                      Data Center Map

                                      SMS Datacenter


                                      » Index » USA » California » Irvine » SMS Datacenter

                                      SMS Datacenter is located in the area Irvine, USA (America), and the colocation data center is carrier neutral. The data center was last updated on 03-10-2018.


                                      Address:
                                      SMS Datacenter
                                      2525 Main Street Suite 120
                                      92614 Irvine
                                      California, USA

                                      » Request quote
                                      » Visit website

                                      Click here to find other data centers
                                      owned and operated by SMS Datacenter.


                                      Profile
                                      Tenants
                                      Connectivity
                                      Request quote
                                      Office space
                                      Rack Cabinets
                                      Dedicated Servers
                                      Suites
                                      Footprints
                                      Virtual Servers
                                      Cages
                                      Hosting of individual servers
                                      Remote Hands

                                      Profile


                                      The SMS Datacenter located in Irvine, California was completely upgraded in 2009 as demand
                                      for capacity has increased for both power and cooling. The PUE (Power Utilization Efficiency) is
                                      always being reduced through technology upgrades. The facility meets the highest availability
                                      standards for housing mission critical computer systems, and is SOC2 audited annually. The purpose
                                      built facility contains a total area of 41,000 square feet and is a fully secure, disaster safe, state of the
                                      art steel structure with complete electrical, mechanical, and environmental back-up systems.
                                      The facility has power generation capability housing both internal and external diesel generators
                                      including three fully 2N redundant Powerware UPS systems. There is over 10,000 gallons of diesel fuel
                                      onsite providing over 72 hours at 100% load of up time. The Automatic Transfer Switches (ATS) are
                                      tested monthly, which can simulate the loss of utility power.
                                      The infrastructure includes a self-contained, automatically controlled environment maintained by over
                                      6.5 million BTUs of air-cooled CRAC units with dedicated roof mounted condensers for the exclusive
                                      use of the raised floor. Each APC cabinet has three phase, 208 Volt redundant powers strips (PDUs)
                                      with both copper patch panels and fiber optic enclosures providing a redundant plug and play fabric.
                                      To prevent unauthorized entry to the facility, SMS Datacenter has 24x7 staff onsite, and a security system
                                      that controls access into and within the building, automatically limiting access to sensitive areas.
                                      Access is also logged automatically within a secure database. Additionally, cameras are installed both
                                      inside and outside the building with DVR recording. With displays in the fully manned Network
                                      Operation Center (NOC) and at the security desk, the premises are constantly monitored by a
                                      comprehensive security system. A uniform guard also operates security after business hours.
                                      There is infrastructure that can be brought online to provide an additional 2000 Amps of Power from a
                                      separate dual substation transformer feed with both generator paralleling gear and ATSs. Redundancy
                                      can also be achieved in cooling by bringing the existing redundant 270 ton cold water chillers online.


                                      SMS Datacenter Pricing/Quotes


                                      If you are interested in receiving a quote for SMS Datacenter, please try our free quote service.

                                      Copyright © Data Center Map - Sitemap
                                      Your guide to colocation data centers, managed hosting, cloud servers etc.