                                      AdNet - DataCity Bucharest


                                      » Index » Romania » Bucharest » AdNet - DataCity Bucharest

                                      AdNet - DataCity Bucharest is located in the area Bucharest, Romania, and the colocation data center is carrier neutral. The data center was last updated on 04-07-2017.


                                      Address:
                                      AdNet Telecom
                                      Blv. Pipera, Nr.1/VI
                                      077190 Voluntari
                                      Ilfov, Romania

                                      » Request quote
                                      » Visit website

                                      Click here to find other data centers
                                      owned and operated by AdNet Telecom.


                                      Profile
                                      Gallery
                                      Tenants
                                      Connectivity
                                      Request quote
                                      Office space
                                      Rack Cabinets
                                      Dedicated Servers
                                      Suites
                                      Footprints
                                      Virtual Servers
                                      Cages
                                      Hosting of individual servers
                                      Remote Hands

                                      Profile


                                      TIER III DESIGN:
                                      Availability higher than 99.982%
                                      Redundant power elements with independent
                                      circuits paths configured in as 1+1
                                      Redundant cooling elements with
                                      independent circuits paths configured in as N+1
                                      Provides concurrent maintenance

                                      ENERGY EFFICIENT:
                                      Optimized IT Equipment arrangement in Cold/Hot Aisle
                                      Advanced multistep cooling control allow for high efficiency
                                      Integration of green energy such as photovoltaic and wind turbine
                                      High performance rectifiers, inverters and accumulators in UPS system
                                      Targeted PUE - Power usage effectiveness lower than 1.3 for 100% load
                                      Actual PUE - 1.75 at 20% Load

                                      IT & TELECOM INFRASTRUCTURE:
                                      IT infrastructure design for TIER III
                                      Multipath optical fiber on 3 circuits
                                      High end border routing equipment Juniper MX series
                                      Data Center L2 and L3 switching performed by Cisco Nexus
                                      Complex evolved virtualization platform based on Cisco UCS, HP 3PAR
                                      storage and VMWare VCenter/Vsphere
                                      Cluster balancing technology from A10 Networks
                                      Advanced traffic anomaly detection and cleaning with Arbor System technology
                                      Complete internal data circuits distribution with Panduit materials

                                      COOLING:
                                      Adiabatic & Free cooling - Indoor for IT Containers:
                                      60 racks with average power of 7 KW arranged in 3 cold aisle with 20 racks each resulting in a total power of 140KW / cold aisle
                                      24 LCU providing 20KW of cooling arranged in 3 cold aisle resulting in 8 units / row with a capacity of cooling of 160KW (7+1)
                                      In-line positioning with racks, Cold-Isle/Hot Isle containment with front to back airflow
                                      Cooling agent: thermic agent with heat transfer properties optimized for whole range of meteorological conditions
                                      Chiller water cooling - Outdoor:
                                      3 x 300KW chiller units with Free Cooling mechanism
                                      "Air-Conditioning" type water cooling - compressors based in 12 steps (4 independent compressors / chiller unit)
                                      N+1 Redundant compressors, ventilators and other components (according to TIER III standards for cooling)
                                      Automation system for adjusting electrical energy consumption
                                      Adiabatic & Free cooling - Indoor for Power containers
                                      4 units 30KW
                                      N+1 redundancy type according to TIER III standards for power supply

                                      POWER & UPS:
                                      Total installed power 480 kW x 2 with redundancy in 2 lines
                                      2 automatic back-up diesel generators one for each line
                                      Accumulators pack - 108 with 100 Ah capacity for each power box
                                      2 UPS of 40 kVA for chiller pumps
                                      2 UPS of 20 kVA for interior modules of inline cooling units
                                      2 heating pumps and 1 ice pillar for extra heat removal before Chillers
                                      1 wind turbine with 2 KW - providing auxiliary power
                                      80 x 250W (20 KW) photovoltaic farm - compensating in extra hot summer days

                                      RACKING & VIRTUALIZATION:
                                      Racks
                                      Hardened steel Racks:
                                      45U racks space proving at least 42U usable IT Equipment
                                      Depth: 1000mm
                                      Width: standard 19''
                                      PDU: for each Rack 2 PDU three-phase power supply of 400V - Maximum power 11 KW redundant/ Rack, each PDU with 24 IEC13 sockets and 6 IEC19 sockets
                                      Assembling on metallic anti vibration and anti seismic system

                                      Virtualization system
                                      Cisco UCS Blade Server System
                                      5 x Blade server chassis each with 8 blade server units installed
                                      Installed processing power ~ 1800 VCPU
                                      Installed memory : 7168 GB
                                      HP 3PAR 7400 Enterprise Storage Dual controller with 200TB of usable space (250TB installed)
                                      Storage: even mix of SAS/NL-SAS disk
                                      Switching: Integrated Cisco switch fabric with extra 32 port 10GB for external connectivity
                                      VMWare VSphere/VCenter Enterprise plus virtualization system

                                      SECURITY SYSTEM:
                                      Complex security system
                                      Fire detection system
                                      Smoke detection sensor
                                      Temperature sensor
                                      Fire extinguisher cylinders
                                      Fire detection station
                                      Exterior fire alarm control panel from fast access from outside
                                      Dual power source, both from main power supply and UPS
                                      Access control module
                                      Emergency fire path - both mechanical and electromagnetic
                                      Magnetic stripe card access
                                      Unlimited user access with multiple roles and rights
                                      Control panel integration with fire detection and extinguisher system - automatic fire path unlocking
                                      Real time reports and history : access type, users, access path, etc.
                                      Surveillance system
                                      HD IP cameras
                                      NVR recording and monitoring
                                      Minimum 30 days data storage in

                                      INFRASTRUCTURE MANAGEMENT:
                                      Complex monitoring and management software suite integrating all hardware and software components installed in the datacenter infrastructure (power elements, cooling elements, security & surveillance, sensors & monitoring devices)
                                      Data center components detailed charts and schematics (racks, cooling, power, surveillance, control access, sensors, etc.)
                                      IT Equipment layout
                                      Power supply, circuits and distribution
                                      Chillers, LCU, cooling paths
                                      Surveillance, access control, firefighting systems
                                      Humidity, temperature, air quality, flood sensor system
                                      Renewable energy controllers
                                      Real time & Historical monitoring for all managed systems
                                      Statistics, Graphics and Analysis of various parameters
                                      Friendly graphical web user interface compatible with most modern browsers

                                      CONNECTIVITY:
                                      Physical connections (L1):
                                      3 paths geographically and logically independent underground optical fiber links - 144 optical wires available
                                      Open Third-party fiber optic interconnection cabinet easily accessible from any underground infrastructure
                                      Logical connections (L2-L3):
                                      Data center node is included in main N x 10Gbps metropolitan multi-ring core network of 2K Telecom, providing high capacity resilient communications with most POP or exchange nodes
                                      Juniper MPLS Switches and Routers provide any type of logical connection (L2 circuits, VPLS, L3 VPN, QinQ, Dark Fiber, TDM transport, etc.)
                                      External connections (National&Internet)
                                      2KTelecom is member of public Internet Exchanges: Interlan, Balkan-IX RoNIX, NxData, IBM Data Center, INES Datacenter, Cyberhost Datacenter
                                      Extra private national interconnection with leading ISP providers improve capacity and latency
                                      Optimized Balanced Access to Internet is achieved through major world wide Internet Carriers (M247/NTT, Telekom/LEVEL3)