                                      Data Center Map

                                      neoDC


                                      » Index » Macedonia » Skopje » neoDC

                                      neoDC is located in the area Skopje, Macedonia (Republic of Macedonia), and the colocation data center is carrier neutral. The data center was last updated on 02-01-2020.


                                      Address:
                                      Neocom
                                      Kuzman Josifovski Pitu 15
                                      1000 Skopje
                                      Macedonia

                                      » Request quote
                                      » Visit website

                                      Click here to find other data centers
                                      owned and operated by Neocom.


                                      Profile
                                      Tenants
                                      Connectivity
                                      Request quote
                                      Office space
                                      Rack Cabinets
                                      Dedicated Servers
                                      Suites
                                      Footprints
                                      Virtual Servers
                                      Cages
                                      Hosting of individual servers
                                      Remote Hands

                                      Profile


                                      Location/Facility
                                      1st floor in Neocom's Head Quarters, with dedicated parking lot for Data Center
                                      Premises of 250m2
                                      Access by freight/service elevator or stairs
                                      Preparation room
                                      Dedicated power and communication trays
                                      Raised antistatic floor
                                      Two physical paths for network, communication and power feed
                                      Server and telecommunication cabinets
                                      Two independent power feed rooms
                                      Two independent interconnection rooms - MeetMe Room
                                      24x7x365 access

                                      Power
                                      2x112KW dedicated power feed on different paths
                                      Own power substation
                                      2 diesel generators with total capacity of over 455KVA
                                      2 independent redundant modular UPS (2x100KW)
                                      2 independent modular rectifiers for -48V (2x12KW) with dedicated batteries
                                      Over 2 tons of UPS batteries

                                      Security
                                      Multilevel granular access control from welcome desk to cabinet
                                      24x7x365 physical security
                                      24x7x365 CCTV surveillance
                                      Auditing all access control events
                                      Cabinet open door alarms

                                      Fire Suppression
                                      Fire resistance of the Data Center for at least 60 minutes
                                      Modular and fireproof system for cable entry
                                      VESDA system
                                      Fire alarm system with multiple zones and multi-level sensors (temperature and smoke)
                                      Automatic fire extinguishing system
                                      Novec 1230 fire extinguishing agent - not harmful to the environment, people and equipment.

                                      Cooling
                                      Controlled temperature of 22oC (+/- 2 oC) with two redundant HVAC
                                      Controlled humidity of 40%-60% with integrated humidifiers and dehumidifiers
                                      Special procedures in place for particles contamination control
                                      Environment monitoring sensors, including water leak and airflow


                                      neoDC Pricing/Quotes